Inspection Status: Approved

Inspection History: PLUMBING - GAS PRESSURE TEST

Permit Number - T03PL00394

Inspection Description - PLUMBING - GAS PRESSURE TEST

Inspection Status - Approved

Date Description Inspector Results Comments
03/13/2003 PLUMBING - GAS PRESSURE TEST Approved IVRS - Inspection 0000*
03/11/2003 PLUMBING - GAS PRESSURE TEST Denied IVRS - Inspection 0999*
1.) PROVIDE AGA OR CSA APPROVED GAS SHUT OFF VALVES AT APPLIANCES.
2.) PROVIDE A SHUT OFF VALVE PRECEDING UNION AT HOUSE CONNECTION.
3.) USE APPROVED TAPE PRIMER ON ALL UNDERGROUND JOINTS. LEAVE CAN ON JOB SITE.
4.) TEST THE ENTIRE GAS SYSTEM INCLUDING PIPE INSIDE THE HOUSE.
RECALL FOR INSPECTION.
5.) GAS PIPE CANNOT RUN UNDER ANY CONCRETE W/ A STRUCTURE SEE SECTION 1211.3.