Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - GAS PRESSURE TEST
Permit Number - T03PL00394
Inspection Description - PLUMBING - GAS PRESSURE TEST
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
03/13/2003 | PLUMBING - GAS PRESSURE TEST | Approved | IVRS - Inspection 0000* | |
03/11/2003 | PLUMBING - GAS PRESSURE TEST | Denied | IVRS - Inspection 0999* 1.) PROVIDE AGA OR CSA APPROVED GAS SHUT OFF VALVES AT APPLIANCES. 2.) PROVIDE A SHUT OFF VALVE PRECEDING UNION AT HOUSE CONNECTION. 3.) USE APPROVED TAPE PRIMER ON ALL UNDERGROUND JOINTS. LEAVE CAN ON JOB SITE. 4.) TEST THE ENTIRE GAS SYSTEM INCLUDING PIPE INSIDE THE HOUSE. RECALL FOR INSPECTION. 5.) GAS PIPE CANNOT RUN UNDER ANY CONCRETE W/ A STRUCTURE SEE SECTION 1211.3. |