Inspection History: PLUMBING - FINAL

Permit Number - T03PL00379

Inspection Description - PLUMBING - FINAL

Inspection Status - Approved

Date Description Inspector Results Comments
02/28/2003 PLUMBING - FINAL Approved IVRS - Inspection 0000*24 PSI TEST OK
ALL CORRECTIONS HAVE BEEN MADE. LEFT GAS CARD.
02/26/2003 PLUMBING - FINAL Denied IVRS - Inspection 0999*
1.) MUST USE RIGHT & LEFT HAND NIPPLES IN LIEU OF UNIONS SEE SECTION: 1211.10 94 UPC.
2.) B VENT FOR WATER HTR MUST TERMINATE 2'-0" ABOVE WALL SEE SECTION: 517.3 94 UPC.
3.) MUST SECURE GAS LINE DROP THAT SEEVES DRYERS AND COMPLETE THIS LINE INTO BLDG.
4.) MUST PROVIDE COMBUSTION AIR FOR WATER HTR RM SEE SECTION 507.3.1. 94 UPC.
5.) RE TEST SYSTEM.
6.) MUST SEAL GAS LINE PENETRATIONS INTO DWELLING.