Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit: T03PL00312

Parcel: 115021910


Addresses:

1512 N 3RD AV


Inspection Status: Approved

Inspection History: PLUMBING - GAS RECONNECT

Permit Number - T03PL00312

Inspection Description - PLUMBING - GAS RECONNECT

Inspection Status - Approved

Date Description Inspector Results Comments
02/27/2003 PLUMBING - GAS RECONNECT Approved IVRS - Inspection 0000*15 PSI TEST OK LEFT GAS CARD.
02/26/2003 PLUMBING - GAS RECONNECT Denied IVRS - Inspection 0999*Unions must be proceeded w/approved shut off values.
2.) T & P drain must terminate outside retest system. recall for final.
02/18/2003 PLUMBING - GAS RECONNECT Not ready for Inspection IVRS - Inspection 0000*INSPECTION CANCELED.
02/14/2003 PLUMBING - GAS RECONNECT Not ready for Inspection IVRS - Inspection 0000*