Permit: T03PL00296

Parcel: 128060890


Addresses:

5681 E 21ST ST

Inspection Status: Approved

Inspection History: PLUMBING - INTERMEDIATE

Date Description Inspector Results Comments
05/22/2003 PLUMBING - INTERMEDIATE Approved IVRS - Inspection 0000*
05/20/2003 PLUMBING - INTERMEDIATE Denied 1) REMOVE OLD ASBESTOS VENT PIPE AND REPLACE WITH DOUBLE WALL PIPE. PROVIDE MINIMUM 1" CLEARANCE AROUND VENT AT ROOF PENETRATIONS. SINGLE WALL ELBOWS CONNECTING TO VENT PIPE MUST HAVE MINIMUM 6" CLEARANCE FROM COMBUSTIBLES. PROVIDE MINIMUM 3 SCREWS IN EACH JOINT 2) T&P DRAIN PIPE MUST EXTEND TO WITHIN 6" OF THE GROUND AND CANNOT HAVE THREADS AT END OF PIPE. CORRECT AND RECALL FOR INSPECTIONS