Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - FINAL
Permit Number - T03PL00272
Inspection Description - PLUMBING - FINAL
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
09/26/2003 | PLUMBING - FINAL | Approved | IVRS - Inspection 0000*/1) SOIL WATER TEST IS OK. 2) P.O.C. OF NEW BLDG SEWER TO EXISTING BLDG SEWER IS OK. 3) OK TO BACKFILL TRENCH. | |
09/23/2003 | PLUMBING - FINAL | Denied | IVRS - Inspection 0999*/ 1) MUST PROVIDE WATER TEST ON SYSTEM TO TOP OF VENT ALL THE WAY TO P.O.C. SECTION 712.2 94 UPC. 2) ABS SCH 40 PIPE MUST HAVE A MINIMUM OF 12" OF COVER. SEE SECTION 313.5 94 UPC. | |
04/04/2003 | PLUMBING - FINAL | Denied | CAN NOT HAVE ABS MATERIAL EXPOSED TO SUNLIGHT. 2.) CAN NOT HAVE DISCHARGE DRAIN WITH ANY TRAPED WATER. 3.) MUST HAVE 3/4" SUPPLYS AND RETURN FULL SIZE. COPPER FLEX CHOKES FULL SIZE. COPPER FLEX. 4.) CAN NOT USE C.O. FOR KITCHEN SINK AS A DRAIN. |
|
03/11/2003 | PLUMBING - FINAL | Denied | IVRS - Inspection 0999*no one home! |