Permit: T03PL00269

Parcel: 131060250


Addresses:

2445 S CRAYCROFT RD

Inspection Status: Approved

Inspection History: PLUMBING - FINAL

Date Description Inspector Results Comments
02/18/2003 PLUMBING - FINAL Approved IVRS - Inspection 0000*
1.) GAS PRESSURE TEST IS OK
2.) GAS SHUT OFF VALVES OK
3.) WATER HTR FLU VENTS, P & T DRAINS ARE EXSISTING.
4.) GAS PACK ON ROOF ARE EXSISTING.
02/15/2003 PLUMBING - FINAL Denied IVRS - Inspection 0999*1.) MUST PROVIDE AGA OR CSA APPROVED GAS SHUT OFF VALVES BEFORE THE UNION FOR 1/2" GAS LINE OUTSIDE OF BLDG.
2.) MUST REMOVE THREAD PROTECTOR IN GAS LINE ROOF AND REPLACE WITH APPROVED COUPLING.
3.) MUST USE DWV COPPER FOR DISCHARGE DRAINS FROM WOK
4.) MUST SCREW DOWN FLU VENT FOR ROASTER WITH 3 SHEET METAL SCREWS PER JOINT.
5.) HAVE APPROVED SHUT OFF VALVES @ EACH APPLIANCE @ TIME OF INSPECTION.