Permit: T03PL00257

Parcel: 13109063B


Addresses:

5819 E 24TH ST

Inspection Status: Approved

Inspection History: PLUMBING - SEWER HCS CONNECT

Date Description Inspector Results Comments
04/18/2003 PLUMBING - SEWER HCS CONNECT Approved IVRS - Inspection 0000*1.) SOIL WATER TEST IS OK
2.) HCS CONNECTION IS OK
3.) P.O.C. OF NEW BLDG. SEWER TO EXSISTING BLDG. DRAIN IS OK
4.) OK TO BACKFILL TRENCH.
04/16/2003 PLUMBING - SEWER HCS CONNECT Not ready for Inspection IVRS - Inspection 0000*NOT READY FOR INSPECTION.
04/15/2003 PLUMBING - SEWER HCS CONNECT Denied 1.) MUST PROVIDE WATER TEST ON SYSTEM UP TO C.O.
2.) MUST SHADE TRENCH TO TOP OF SEWER PIPE AND TO SIDE OF TRENCH
3.) MUST EXPOSE LIP OF SEPTIC TANK AND PUMP TANK AND CORE DRILL OR BREAK BOTTOM OF TANK. DO NOT FILL UNTIL INSPECTION.
4.) CAN NOT HAVE THREADED FITTINGS BELOW GRADE MUST USE COMBO FOR C.O. TO GRADE.
5.) MUST PROVIDE TWO WAY C.O. (2) COMBOS FOR BOTH DWELLING.