Permit: T03PL00240

Parcel: 120075850

Inspection Status: Approved

Inspection History: PLUMBING - FINAL

Date Description Inspector Results Comments
03/04/2003 PLUMBING - FINAL Approved 1.) GAS PRESSURE TEST IS OK
2.) GAS SHUT OFF VALVES OK
3.) WATER HTR FLU VENT P & T VALVE & DRAIN IS OK
4.) NOTE OWNER WILL PLUG & CAP GAS SUPPLY TO RANGE AND CUT OFF THREADS @ END OF P & T DRAIN.
03/03/2003 PLUMBING - FINAL Denied IVRS - Inspection 0999*1. THERE ARE FOUR APT'S AT 351 W. PENNSYLVANIA.
NONE OF THEM HAS AN ADDRESS OR APT. NUMBER
02/27/2003 PLUMBING - FINAL Denied IVRS - Inspection 0999*NO ONE HOME
NO ANSWER @ 490-5546.
02/21/2003 PLUMBING - FINAL Denied IVRS - Inspection 0999*1.) REMOVE UNIONS FROM GAS LINE & USE REVERSE THREAD COUPLINGS & NIPPLES.
2.) PROVIDE MIN 3 SCREWS ON ALL JOINTS OF WATER HEATER VENT.
3.) GAS FLEX CANNOT PENETRATE THE KITCHEN CABINET.
4.) RETEST SYSTEM. RECALL FOR INSPECTION.