Permit: T03PL00179

Parcel: 131050830


Addresses:

5125 E FERRY DR

Inspection Status: Approved

Inspection History: PLUMBING - GAS PRESSURE TEST

Date Description Inspector Results Comments
08/17/2004 PLUMBING - GAS PRESSURE TEST Approved IVRS - Inspection :*/APPROVED-25PSI AIR TEST FORM MOTER NOW 1" SCOTCH COAT UNDER GROUND TO BUILDING TO DRYER LOCATION, STOVE, FURANCE & WATER HEATER
03090-NOT READY
1) PROVIDE BONDING OF BUILDING GAS PIPING.
2) INSTALL WATER HEATER, PROVIDE CITY SIGHED POTITION OF APPROVAL FOR ALTERNATE FORM OF WATER HEATER TEMPORATURGE & PRESSURE ROLLER WITH PROPER INSTALLATION
3)EXTEND VENT FROM WATER HEATER & FURANCE 3' ABOVE TOP OF COOLER.
04/14/2004 PLUMBING - GAS PRESSURE TEST Not ready for Inspection IVRS - Inspection 0000*/ 94 UPC SEC. 1211.3 - 1) NO GAS PIPING TO BE INSTALLED UNDER A BLDG OR STRUCTURE. 2) PLEASE PROVIDE BEFORE UNION OF BLDG SHUT OFF OR PROVIDE RIGHT/LEFT NIPPLE AND COUPLING.