Permit: T03PL00123

Parcel: 11720016E


Addresses:

222 S CHURCH AV


Inspection Status: Approved

Inspection History: PLUMBING - FINAL

Permit Number - T03PL00123

Inspection Description - PLUMBING - FINAL

Inspection Status - Approved

Date Description Inspector Results Comments
01/31/2003 PLUMBING - FINAL Approved IVRS - Inspection 0000*10PSI TEST OK
LEFT GAS CARD ALL CORRECTIONS HAVE BEEN MADE.
01/29/2003 PLUMBING - FINAL Partial Approval IVRS - Inspection 0000*1.) SHUT OFF VALVE TO WATER HEATER MUST BE WRITTEN 3' OF CONNECTION TO APPLIANCE.
2.) PROVIDE MIN 1" CLEARANCE AROUND WATER HEATER VENT.
3.) GAS FLEX CANNOT EXCEED 3'
4.) REMOVE FLEX FROM T & P DRAIN
5.) PROVIDE COMBUSTION AIR TO WATER HEATER ROOM RETEST SYSTEM AFTER RELOCATING GAS VALVE.
01/23/2003 PLUMBING - FINAL Denied 1.) SECURE PERMIT FOR WATER HEATER. CALL GAS AND WATER HEATER INSPECTION AT THE SAME TIME AND BOTH INSPECTIONS CAN BE PERFORMED SIMULTANEOUSLY.