Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit: T03PL00120

Parcel: 127071190


Addresses:

5236 E 7TH ST

Inspection Status: Approved

Inspection History: PLUMBING - FINAL

Date Description Inspector Results Comments
01/27/2003 PLUMBING - FINAL Approved PETITION OF APPEAL APPROVED BY DAVE MANN CASE #2003-07.
TEST ON COMPLETE SYSTEM TO EXISTING FURNACE OK
PROVIDE MID STORY ANCHOR ON GAS LINE OUTSIDE CALL GAS CO. 889-1888.
01/22/2003 PLUMBING - FINAL Denied IVRS - Inspection 0999*1.) PROVIDE A GAS SHUT OFF VALVE AT UNION OUTSIDE.
2.) ADD WATER HEATER TO PERMIT.
3.) REMOVE UNION FROM CLOSET.
4.) PROVIDE MIN 10LB. TEST ON ENTIRE SYSTEM.
5.) PROVIDE PETITION OF APPEAL FOR T&P DRAIN LINE ALTERNATE METHOD.