Permit: T03PL00096

Parcel: 119211920

Inspection Status: Approved

Inspection History: PLUMBING - FINAL

Date Description Inspector Results Comments
01/31/2003 PLUMBING - FINAL Approved IVRS - Inspection 0000*
01/17/2003 PLUMBING - FINAL Denied COMPLETE ALL NOTES PRIOR TO CALLING FOR INSP.
01/16/2003 PLUMBING - FINAL Denied IVRS - Inspection 0999*
1.) ABS AND PVC MAY NOT BE INTERMINGLED
2.) DRAIN LINE MAY NOT BE REDUCED, TO BE GRAVITY DRAIN.
3.) ABS MAY NOT BE TAPPED OR THREADED FOR MAKING CONNECTION.
4.) PVC MAY NOT BE USED AS DRAIN LINE IN AN EXPOSED EXTERIOR LOCATION.
5.) HOSE BIBB REQUIRES VACUUM BREAKER
6.) INDIRECT WASTE? EXCEEDS 15'
7.) RANG DOORBELL NO RESPONSE 1:05PM.