Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - FINAL
Permit Number - T03PL00095
Inspection Description - PLUMBING - FINAL
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
01/17/2003 | PLUMBING - FINAL | Approved | 1.) REMOVE CAPPED BRANCH IN YARD OR PROVIDE APPROVED ISOMETRIC DRAWING SHOWING DEVELOPED LENGTH AND BTU CONSUMPTION. IMPORTANT TO INCLUDE ALL PROPOSED BRANCH PIPING AND APPLIANCES. 2.) FLEX CONNECTOR TO WATER HEATER UNDERSIZED AND DAMAGED. 3.) T & P RELIEF DRAIN TO BE FULL SIZE, AND TO APPROVED LOCATION. 4.) REMOVE TAPE BETWEEN VENT CONNECTOR AND VENT. 5.) IS VENT COLLAR INSTALLER PER MANUFACTURERS RECOMMENDATION? REINSPECTED 3:00PM TEE REMOVED FROM LINE 2.) FLEX CONNECTOR REPLACED OK TO BACKFILL 3.) T & P RELIEF DRAIN TO BE CORRECTED AT TIME OF WATER HEATER REPLACEMENT. |
|
01/16/2003 | PLUMBING - FINAL | Partial Approval | .) THIS INSPECTION IS FOR A GAS RECONNECT GAS PIPING TO INTERIOR SPACE HEADER, AND MULTIPLE ROOF TOP UNITS OK. FLEXES AND VALVES OK PRESSURE TEST OK OK FOR GAS 2.) UCC LEFT AT METER SET 3.) IT IS NOT PART OF THIS INSPECTION BUT BE ADVISED THAT THE ROOF TOP UNITS NEED SOME MAINTENANCE AND REPAIR, ESPECIALLY THE CONDENSATE DRAINS. |