Permit: T03PL00095

Parcel: 123141420


Addresses:

842 E LESTER ST


Inspection Status: Approved

Inspection History: PLUMBING - FINAL

Permit Number - T03PL00095

Inspection Description - PLUMBING - FINAL

Inspection Status - Approved

Date Description Inspector Results Comments
01/17/2003 PLUMBING - FINAL Approved 1.) REMOVE CAPPED BRANCH IN YARD OR PROVIDE APPROVED ISOMETRIC DRAWING SHOWING DEVELOPED LENGTH AND BTU CONSUMPTION. IMPORTANT TO INCLUDE ALL PROPOSED BRANCH PIPING AND APPLIANCES.
2.) FLEX CONNECTOR TO WATER HEATER UNDERSIZED AND DAMAGED.
3.) T & P RELIEF DRAIN TO BE FULL SIZE, AND TO APPROVED LOCATION.
4.) REMOVE TAPE BETWEEN VENT CONNECTOR AND VENT.
5.) IS VENT COLLAR INSTALLER PER MANUFACTURERS RECOMMENDATION? REINSPECTED 3:00PM
TEE REMOVED FROM LINE
2.) FLEX CONNECTOR REPLACED OK TO BACKFILL
3.) T & P RELIEF DRAIN TO BE CORRECTED AT TIME OF WATER HEATER REPLACEMENT.
01/16/2003 PLUMBING - FINAL Partial Approval .) THIS INSPECTION IS FOR A GAS RECONNECT
GAS PIPING TO INTERIOR SPACE HEADER, AND MULTIPLE ROOF TOP UNITS OK.
FLEXES AND VALVES OK
PRESSURE TEST OK
OK FOR GAS
2.) UCC LEFT AT METER SET
3.) IT IS NOT PART OF THIS INSPECTION BUT BE ADVISED THAT THE ROOF TOP UNITS NEED SOME MAINTENANCE AND REPAIR, ESPECIALLY THE CONDENSATE DRAINS.