Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit: T03PL00028

Parcel: 119220480


Addresses:

1992 W MERLIN RD

Inspection Status: Approved

Inspection History: PLUMBING - FINAL

Date Description Inspector Results Comments
01/17/2003 PLUMBING - FINAL Approved IVRS - Inspection 0000*
01/14/2003 PLUMBING - FINAL Denied IVRS - Inspection 0999*NO ONE HOME.
01/10/2003 PLUMBING - FINAL Denied IVRS - Inspection 0999*1.) PROVIDE A PRESSURE TEST DUE TO A NEW SHUT OFF VALUE HAS BEEN INSTALLED.
2.) REMOVE ALL PLUMBER TAPE & REPLACE WITH CLAMPS AS REST OF LINE.
3.) GAS LINE COMING DOWN TO METER NEEDS TO BE STABALIZED.
4.) GAS LINE NEEDS TO BE BONDED TO WATER LINE AND ELECTRICAL PANEL.
5.) WITH A #6 COPPER ALL APPLIANCES UP TO CODE.