Permit: T03OT01515

Parcel: 110180200


Addresses:

2802 N RALPH AV

Inspection Status: Approved

Inspection History: ELECTRIC - FINAL

Date Description Inspector Results Comments
12/17/2003 ELECTRIC - FINAL Approved
11/18/2003 ELECTRIC - FINAL Not ready for Inspection IVRS - Inspection 0000*/ / 1) KITCHEN COUNTER TOP OUTLETS TO BE GFCI PROTECTED 2) FILL UNUSED OPENING IN SWITCH PLATE 3) CORD NOT TO PASS THRU DOOR WAY 4) BATHROOM OUTLETS TO BE GFCI PROTECTED-NOT ALLOWED IN LIGHT-ALSO TO BE WITHIN 3' OF BASIN 5) SMOKE DETECTORS TO BE INTER LOCKED
11/13/2003 ELECTRIC - FINAL Denied IVRS - Inspection 0999*/ MUST BE OPEN FOR INSPECTION, CALL BACK RESCHEDULE AND LEAVE MESSAGE.