Inspection Status: Approved
Inspection History: SIGN ELECTRIC
| Date |
Description |
Inspector |
Results |
Comments |
| 03/23/2004 |
SIGN ELECTRIC |
|
Approved |
IVRS - Inspection 0000* |
| 03/18/2004 |
SIGN ELECTRIC |
|
Denied |
IVRS - Inspection 0999$/ 1) CALLED AT 8:40 FOR MEETING WITH CONTRACTOR, NO ANSWER AND COULD NOT LEAVE MESSAGE |
| 03/10/2004 |
SIGN ELECTRIC |
|
Partial Approval |
IVRS - Inspection 0000*/ 1) SUPPORT FLEX CONDUIT AS PER CODE. 2) AN APPROVED FITTING IS NEEDE AT JUNCTION BOX. 3) GROUND JUNTION BOXES. 4) MISSING JUNCTION BOX COVER PLATE. |
| 12/11/2003 |
SIGN ELECTRIC |
|
Not ready for Inspection |
IVRS - Inspection 0000* 1) NEON SPLICE BOOT TO BE LISTED FOR WET LOCATION, PLEASE VERIFY LISTING. 2) BOND TRANSFORMER ENCLOSURES. 3) TIGHTEN LOOSE FITTINGS. 4) NO POWER CONNECTORS AT THIS TIME. |