Permit: T03OT01333

Parcel: 113100050


Addresses:

2745 N CAMPBELL AV


Inspection Status: Approved

Inspection History: PLUMBING - FINAL

Permit Number - T03OT01333

Inspection Description - PLUMBING - FINAL

Inspection Status - Approved

Date Description Inspector Results Comments
01/21/2004 PLUMBING - FINAL Approved IVRS - Inspection 0000*/ 1) CORRECTIONS HAVE BEEN MADE. TESTING ON BACK FLOW DEVICES OK
01/20/2004 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection 0000*/ 1) SEE NOTE #1 FROM 1-15-04, NEED KITCHEN EQUIPMENT PLAN. TWO COMP OF 3 COMP SINK INDIRECTLY WASTED [COVERED] TO FLOOR SINK. USE DRAINAGE FITTINGS ON 3 COMP SINK. 2) SODA MACHINE AND ICE MACHINE CERTS ON FILE WITH TUCSON WATER. 3) ICE MACHINE DRAIN MAY NOT BE COMBINED WITH ICE BINS. 4) CABLE RESTRAINTS REQUIRED AT FRYER.
01/16/2004 PLUMBING - FINAL Not ready for Inspection PLEASE PROVIDE TESTING ON BACKFLOW DEVICE AND CALL FOR FINAL.
01/15/2004 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection 0000*/ 1) PROVIDE APPROVED PLAN. 2) BACKFLOW PROTECTION SODA. 3) BACKFLOW DEVICE FOR ICE. 4) FLOW CONTROL FOR GREASE TRAP. PROPER AIR GAP ON INDIRECT WASTE LINES. IS GAS METER ON??