Inspection Status: Approved
Inspection History: SIGN ELECTRIC
| Date |
Description |
Inspector |
Results |
Comments |
| 08/19/2003 |
SIGN ELECTRIC |
|
Approved |
IVRS - Inspection 0000*/ 1) OK SIGN |
| 06/26/2003 |
SIGN ELECTRIC |
|
Denied |
IVRS - Inspection 0999*/ 1) CONDUIT TO BE SUPPORTED AS PER CODE 2) PVC TO BE SCHEDULE 80 3) SIGN COVER TO SEAL FOR WEATHER PROOF 4) JUNCTION BOX TO BE BONDED 5) ? FLEX CONNECTORS AND CONDUIT FITTINGS 6) NO MORE THAN 360 DEGREE IN CONDUIT RUN 7) ELBOWS TO BE ACCESSIBLE 8) LABEL NEW CIRCUIT 9) WE HAVE MULTIPLE TERMINATIONS AT GROUND LUG 10) USE BREAKER LISTED BY PANEL MANUFACTURER 11) CORRECTLY TERMINATE ALL CONDUCTORS IN TIME CLOCK 12) WORK TO BE PERFORMED BY LICENSED C-11 ELECTRICAL CONTRACTOR PLEASE VERIFY |