Permit: T03ME00574

Parcel: 135100810


Addresses:

2308 S CALLE ZAMORA

Inspection Status: Approved

Inspection History: MECHANICAL - FINAL

Date Description Inspector Results Comments
10/28/2003 MECHANICAL - FINAL Approved IVRS - Inspection 0000*/ ALL CORRECTIONS HAVE BEEN MADE.
10/17/2003 MECHANICAL - FINAL Denied IVRS - Inspection 0999*/ 1) 3/8" I.D. GAS FLEX CONNECTOR ON ROOF NOT ADEQUATE FOR 120,000 BTU. FURNACE. USE 1/2" I.D. 2) SEWER VENT MUST BE 10' AWAY OR 2' ABOVE FRESH AIR INTAKE ON A/C UNIT. 3) PROVIDE A PERMIT FOR ELEC. UPGRADE AND INSPECTION. 4) SECURE CONDENSATE DRAIN LINE TO WALL. RE-CALL FOR INSPECTION.