Inspection History Details
Inspection Status: Partial Approval
Inspection History: MECHANICAL - FINAL
Permit Number - T03ME00571
Inspection Description - MECHANICAL - FINAL
Inspection Status - Partial Approval
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
10/22/2003 | MECHANICAL - FINAL | Partial Approval | IVRS - Inspection 0000* | |
10/22/2003 | MECHANICAL - FINAL | Denied | IVRS - Inspection 0999*/ 1) NEW UNIT REQUIRES A 1" CONDENSATE DRAIN LINE. PROVIDE 1" DRAIN LINE ALL THE WAY TO DISCHARGE AREA. 2) PROVIDE A GAS SHUT OFF VALVE WITHIN 3' OF CONNECTION OF EQUIPMENT. 3) PROVIDE A MECH. PERMIT FOR NEW CARRIER UNIT ON ROOF. RECALL FOR INSPECTION. |