Permit: T03ME00550

Parcel: 131081250


Addresses:

6071 E 27TH ST

Inspection Status: Approved

Inspection History: MECHANICAL - FINAL

Date Description Inspector Results Comments
10/22/2003 MECHANICAL - FINAL Approved IVRS - Inspection 0000*
10/17/2003 MECHANICAL - FINAL Denied IVRS - Inspection 0999*/ PROVIDE A MIN. 10 LB TEST ON ALL NEW GAS PIPING. RE-CALL FOR INSPECTION.
10/08/2003 MECHANICAL - FINAL Partial Approval IVRS - Inspection 0000*/ ELEC. DISCONNECT IS OVERFUSED AT 60 AMP. 40 AMP IS MAX FUSE SIZE. COULD NOT CHECK AMPS ON CIRCUIT BREAKER - NOBODY HOME. PLEASE RECALL FOR INSP. WHEN SOMEONE WILL BE HOME. I NEED TO SEE WHERE THE NEW GAS PIPE WAS CONNECTED. IF THERE IS MORE THAN 1 NEW FITTING INSIDE THE HOUSE, YOUR CONTRACTOR WILL HAVE TO PROVIDE A PRESSURE TEST.