Permit: T03ME00548

Parcel: 12710178B

Inspection Status: Approved

Inspection History: MECHANICAL - FINAL

Permit Number - T03ME00548

Inspection Description - MECHANICAL - FINAL

Inspection Status - Approved

Date Description Inspector Results Comments
12/31/2009 MECHANICAL - FINAL Approved
10/06/2003 MECHANICAL - FINAL Denied IVRS - Inspection 0999*/ YOU CANNOT TERMINATE CONDENSATE INTO A ROOF DRAIN THAT DICHARGES INTO THE PARKING LOT. CALL ME AT 909-4712 TO DICUSS ALTERNATE METHODS.
09/25/2003 MECHANICAL - FINAL Denied IVRS - Inspection 0999*/1) CONDENSATE DRAINS CANNOT BE DIRECTLY CONNECTED TO A SEWER VENT. THIS CODE CHANGED 3 YEARS AGO. 2) ANY SEWER VENTS WITHIN 10' OF A FRESH AIR INTAKE MUST BE 10' AWAY OR 2' HIGHER THAN INTAKE OPENING.