Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Inspection History Details
Inspection Status: Approved
Inspection History: MECHANICAL - FINAL
Permit Number - T03ME00548
Inspection Description - MECHANICAL - FINAL
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
12/31/2009 | MECHANICAL - FINAL | Approved | ||
10/06/2003 | MECHANICAL - FINAL | Denied | IVRS - Inspection 0999*/ YOU CANNOT TERMINATE CONDENSATE INTO A ROOF DRAIN THAT DICHARGES INTO THE PARKING LOT. CALL ME AT 909-4712 TO DICUSS ALTERNATE METHODS. | |
09/25/2003 | MECHANICAL - FINAL | Denied | IVRS - Inspection 0999*/1) CONDENSATE DRAINS CANNOT BE DIRECTLY CONNECTED TO A SEWER VENT. THIS CODE CHANGED 3 YEARS AGO. 2) ANY SEWER VENTS WITHIN 10' OF A FRESH AIR INTAKE MUST BE 10' AWAY OR 2' HIGHER THAN INTAKE OPENING. |