Inspection Status: Approved
Inspection History: MECHANICAL - FINAL
| Date |
Description |
Inspector |
Results |
Comments |
| 11/10/2003 |
MECHANICAL - FINAL |
|
Approved |
ALL CORRECTIONS HAVE BEEN MADE |
| 10/20/2003 |
MECHANICAL - FINAL |
|
Denied |
IVRS - Inspection 0920*/ 1) SORRY I MISSED YOU. PLEASE HAVE CONTRACTORS RESCHEDULE WHEN ACCESS TO A/C INSTALLATION IS AVAILABLE |
| 07/31/2003 |
MECHANICAL - FINAL |
|
Denied |
1) WIRING METHODS USED AT CONDENSOR NOT TO CODE. 2) PROVIDE A TRAP ON CONDENSATE DRAIN. PLUG SECONDARY DDRAIN OUTLET. 3) PROVIDE A HIGH COMBUSTION AIR OPENING IN FURNACE CLOSET MIN 100 SQ IN. 4) CONDENSATE CANNOT TERMINATE INTO A SEWER VENT IF IT CAN BE TERMINATED TO THE GROUND. RECALL FOR INSP |