Permit: T03ME00319

Parcel: 131031590


Addresses:

5209 E 28TH ST

Inspection Status: Approved

Inspection History: MECHANICAL - FINAL

Date Description Inspector Results Comments
07/21/2003 MECHANICAL - FINAL Approved IVRS - Inspection 0000*
07/14/2003 MECHANICAL - FINAL Denied IVRS - Inspection 0999*/ 1) PROVIDE A ROOF JACK WHERE ELEC. CONDUIT PENETRATES THE ROOF. 2) YOU CAN NOT USE A CHASE NIPPLE TO CONNECT TO A CIRCUIT PANEL. USE A CLOSE NIPPLE W/ LOCK NUTS. PROVIDE A BOND BUSHING IF USING REDUCING WASHERS AT KNOCK OUT TO CREATE AN ADEQUATE BOND WITH PANEL. SEE SECTION 110-3, ARTICLE 250, 1999 NEC. LABEL CIRCUIT BREAKER. 3) TERMINATE CONDENSATE DRAIN LINE WITH A 1" AIR GAP OVER SEWER PIPE. DO NOT RUN THE DRAIN LINE INTO THE VENT PIPE.