Inspection History Details
Inspection Status: Approved
Inspection History: MECHANICAL - FINAL
Permit Number - T03ME00293
Inspection Description - MECHANICAL - FINAL
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
08/15/2003 | MECHANICAL - FINAL | Approved | IVRS - Inspection 0000* | |
06/30/2003 | MECHANICAL - FINAL | Denied | IVRS - Inspection 0920*/ 1) DO NOT CALL FOR INSPECTION IF NOBODY IS GOING TO BE HOME. NEXT TIME I WILL CHARGE YOU A RE-INSPECTION FEE | |
06/27/2003 | MECHANICAL - FINAL | Denied | IVRS - Inspection 0920*/ 1) PLEASE CALL FOR AN INSPECTION WHEN SOMEONE WILL BE HOME | |
06/12/2003 | MECHANICAL - FINAL | Partial Approval | IVRS - Inspection 0000*/ 1) DISCHARGE HOSE IS KINKED WHERE IT CONNECTS TO THE CONDENSATE PUMP 2) SCREW FURNACE VENT CONNECTOR TO OUTLET ON FURNACE AND CONNECTION TO DOUBLE WALL PIPE 3) ISOLATE COPPER REFER LINE FROM CONTACTING STEEL UNISTRUT CLAMPS 4) PROVIDE A ROOF JACK WHERE ELECTRIC CONDUIT PENETRATE THE ROOF 5) DO NOT EXTEND DISCHARGE TUBING FROM CONDENSATE PUMP INTO THE SEWER VENT TERMINATE ABOVE THE VENT WITH AN AIR GAP. CLAMP THE TUBING TO THE VENTS 6) RECALL FOR INSPECTION |