Permit: T03ME00293

Parcel: 136173950


Addresses:

8351 E CAMARILLO DR


Inspection Status: Approved

Inspection History: MECHANICAL - FINAL

Permit Number - T03ME00293

Inspection Description - MECHANICAL - FINAL

Inspection Status - Approved

Date Description Inspector Results Comments
08/15/2003 MECHANICAL - FINAL Approved IVRS - Inspection 0000*
06/30/2003 MECHANICAL - FINAL Denied IVRS - Inspection 0920*/ 1) DO NOT CALL FOR INSPECTION IF NOBODY IS GOING TO BE HOME. NEXT TIME I WILL CHARGE YOU A RE-INSPECTION FEE
06/27/2003 MECHANICAL - FINAL Denied IVRS - Inspection 0920*/ 1) PLEASE CALL FOR AN INSPECTION WHEN SOMEONE WILL BE HOME
06/12/2003 MECHANICAL - FINAL Partial Approval IVRS - Inspection 0000*/ 1) DISCHARGE HOSE IS KINKED WHERE IT CONNECTS TO THE CONDENSATE PUMP 2) SCREW FURNACE VENT CONNECTOR TO OUTLET ON FURNACE AND CONNECTION TO DOUBLE WALL PIPE 3) ISOLATE COPPER REFER LINE FROM CONTACTING STEEL UNISTRUT CLAMPS 4) PROVIDE A ROOF JACK WHERE ELECTRIC CONDUIT PENETRATE THE ROOF 5) DO NOT EXTEND DISCHARGE TUBING FROM CONDENSATE PUMP INTO THE SEWER VENT TERMINATE ABOVE THE VENT WITH AN AIR GAP. CLAMP THE TUBING TO THE VENTS 6) RECALL FOR INSPECTION