Inspection History Details
Inspection Status: Denied
Inspection History: MECHANICAL - FINAL
Permit Number - T03ME00275
Inspection Description - MECHANICAL - FINAL
Inspection Status - Denied
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 06/06/2003 | MECHANICAL - FINAL | Denied | IVRS - Inspection 0999*/ 1) CRIMP ON SINGLE WALL VENT CONNECTOR RAN BACKWARDS. SHOULD GO WITH AIR FLOW. PROVIDE MINIMUM 3 SCREWS IN EACH JOINT ON VENT CONNECTOR. PROVIDE MINIMUM 6" CLEARANCE WHERE PVC PASSES IN FRONT OF FURNACE VENT 1" IF USING DOUBLE WALL 2) PROVIDE A TRAP ON CONDENSATE DRAIN LINE 3) PROVIDE ROMEX CONNECTOR WHERE ELECTRIC WIRES PENETRATE THE CABINET OF THE CONDENSING UNIT. RECALL FOR INSPECTION |