Permit: T03ME00224

Parcel: 134242020


Addresses:

825 S FORDHAM DR

Inspection Status: Approved

Inspection History: MECHANICAL - FINAL

Date Description Inspector Results Comments
06/17/2003 MECHANICAL - FINAL Approved IVRS - Inspection 0000*/ALL CORRECTIONS HAVE BEEN MADE.
05/12/2003 MECHANICAL - FINAL Denied IVRS - Inspection 0999*1.) PROVIDE MIN 3. SCREWS IN EACH JOINT ON VENT CONNECTOR.
2.) PROVIDE HOSE CLAMPS ON PLASTIC HOSE ON PUMP.
3.) SINGLE WALL VENT CONNECTOR MUST HAVE CLEARANCE FROM RUBATEX.
4.) BLOCK & CLAMP ELEC. CONDUIT. PROVIDE ROOF JACKS AT ROOF PENETRATIONS. BLOCK & CLAMP REFER LINES. GLUE JOINTS ON RUBATLEX
5.) LB AT ELEC. PANEL NEEDS TO BE BONDED. COORDINATE WITH YOUR ELECTIRICAN.
RECALL FOR INSPECTION.