Permit: T03ME00071

Parcel: 126051490


Addresses:

3926 E 1ST ST

Inspection Status: Approved

Inspection History: MECHANICAL - FINAL

Date Description Inspector Results Comments
04/07/2003 MECHANICAL - FINAL Approved IVRS - Inspection 0000*
03/27/2003 MECHANICAL - FINAL Denied IVRS - Inspection 0935$THIS PVC CONDENSATE PIPING MUST PAINTED TO PROTECT MATL. FROM CRACKING AND DRAINING COLD WATER ON HOT ROOF SURFACE.
UNABLE TO CALL CONTRACTOR INCORRECT PHONE NUMBER.
PLEASE HAVE CONTRACTOR RETURN. AND MAKE NECESSARY CORRECTIONS.
02/10/2003 MECHANICAL - FINAL Denied IVRS - Inspection 0999*1.) CONDENSATE CANNOT TERMINATE INTO A SEWER VENT. GO TO WITHIN 6" OF THE GROUND. USE A ROOF JACK IF PENETRATING THE ROOF. PAINT EXPOSED PVC W/LATEX PAINT.
2.) PROVIDE A BUSHING OR CHASE NIPPLE WHERE ELEC. WIRES ENTER THE A/C UNIT.
CORRECT & RECALL FOR INSPECTION.