Permit: T03ME00013

Parcel: 111084200


Addresses:

2549 N RICHEY BL

Inspection Status: Approved

Inspection History: MECHANICAL - FINAL

Date Description Inspector Results Comments
05/22/2003 MECHANICAL - FINAL Approved IVRS - Inspection 0000*/ 1) THIS LOOKS REAL GOOD, CONDENSATE MUST BE PROPERLY DRAINED. IF ALLOWED TO RUN ON ROOF, COLD WATER DRAINED ON HOT ROOF SURFACE RUINS ROOF 2) IF ALLOWED TO DRIP DOWN, IT BECOMES WET GOOEY, DISCOLORS WALLS AND RIOLE WALKS AND BECOMES A WALKING HAZARD. ROOF DRAIN ONTO SOIL IS PERFECT
04/16/2003 MECHANICAL - FINAL Partial Approval IVRS - Inspection 0000*
1.) ELECT FUSING.
DATA PLATE, NOT COMPLETED. DOES THIS UNIT HOME AUXILARY HEAT STRIP? YES?NO?
IF YES, WHAT SIZE. NOTE HEAT PUMP ONLY, MAX. FUSE SIZE IS 40 AMPS.
UNIT NOW FUSED AT 50 AMPS??
MARK CORRECT SIZE HEAT STRIP AND MARK/LEAVE UNIT PROPERLY FUSED.
2.) CONDENSATE TERMINATION OK IF DOWN SPOUT IS ATTACHED TO LEADER HEAD CONALIE AT REAR PARAPET WALL. CAN'T DUMP THREE CANOLIE IF DOWN SPOUT IS NOT IN PLACE.