Inspection History Details
Inspection Status: Denied
Inspection History: ELECTRIC - FINAL
Permit Number - T03EL02472
Inspection Description - ELECTRIC - FINAL
Inspection Status - Denied
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
06/10/2004 | ELECTRIC - FINAL | Denied | IVRS - Inspection : The wiring is not complete or does not comply with code.| 245*/ 1) WHAT HAPPENED TO THE BREAKERS IN THE SERVICE PANEL? IF NOT TO BE USED INSTALL BLANKS TO FILL THE HOLES. 2) INSTALL PERM. ADDREE LABEL ON SERVICE ENCLOSURE. |
|
05/24/2004 | ELECTRIC - FINAL | Partial Approval | IVRS - Inspection :* | |
03/02/2004 | ELECTRIC - FINAL | Denied | IVRS - Inspection 0245*/ 1) BRACE COOLER POWER BOX ON ROOF. 2) REPLACED SERVICE PANEL WITH NEW PANEL. INSTALL BUSHING ON BACK KO TO PROTECT BRANCH WIRING, USE APPROVED WIRE CONNECTOR FOR GROUND SPLICE. ALL CIRCUIT BREAKERS MUST BE SAME MANUF. AS PANEL. 3) INSTALL COOLER, HEATING UNITS.4) INSTALL MISSING LIGHT FIXTURES, SWITCHES, RECEPTACLES. DO NOT INSTALL GROUNDING TYPE RECEPTACLES ON AN UNGROUNDED SYSTEM UNLESS A GFCI RECEPT. IS AHEAD OF THE CIRCUIT. HOUSE IS UNOCCUPIED, THEREFORE REQUIRES A C-11 LICENSED ELECTRICAL CONTRACTOR TO DO WORK. LEAVE NAME AND PHONE # OF CONTRACTOR. |