Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit: T03EL02472

Parcel: 138142190


Addresses:

234 W CALLE ANTONIA


Inspection Status: Denied

Inspection History: ELECTRIC - FINAL

Permit Number - T03EL02472

Inspection Description - ELECTRIC - FINAL

Inspection Status - Denied

Date Description Inspector Results Comments
06/10/2004 ELECTRIC - FINAL Denied IVRS - Inspection :
The wiring is not complete or does not comply with code.| 245*/ 1) WHAT HAPPENED TO THE BREAKERS IN THE SERVICE PANEL? IF NOT TO BE USED INSTALL BLANKS TO FILL THE HOLES. 2) INSTALL PERM. ADDREE LABEL ON SERVICE ENCLOSURE.
05/24/2004 ELECTRIC - FINAL Partial Approval IVRS - Inspection :*
03/02/2004 ELECTRIC - FINAL Denied IVRS - Inspection 0245*/ 1) BRACE COOLER POWER BOX ON ROOF. 2) REPLACED SERVICE PANEL WITH NEW PANEL. INSTALL BUSHING ON BACK KO TO PROTECT BRANCH WIRING, USE APPROVED WIRE CONNECTOR FOR GROUND SPLICE. ALL CIRCUIT BREAKERS MUST BE SAME MANUF. AS PANEL. 3) INSTALL COOLER, HEATING UNITS.4) INSTALL MISSING LIGHT FIXTURES, SWITCHES, RECEPTACLES. DO NOT INSTALL GROUNDING TYPE RECEPTACLES ON AN UNGROUNDED SYSTEM UNLESS A GFCI RECEPT. IS AHEAD OF THE CIRCUIT. HOUSE IS UNOCCUPIED, THEREFORE REQUIRES A C-11 LICENSED ELECTRICAL CONTRACTOR TO DO WORK. LEAVE NAME AND PHONE # OF CONTRACTOR.