Permit: T03EL02356

Parcel: 136380350


Addresses:

7254 E FREESTONE DR

Inspection Status: Approved

Inspection History: ELECTRIC - FINAL

Date Description Inspector Results Comments
12/11/2003 ELECTRIC - FINAL Approved IVRS - Inspection 0000*SENT TO TEP ON 12/12/03AM
12/08/2003 ELECTRIC - FINAL Denied IVRS - Inspection 0999*/ 1) 30 AMP RECEPTACLE IN ENCLOSED PORCH-REMOVE OR CORRECT INSTALLATION 2) SWITCH IN STORAGE ROOM TO BE EXTENDED OUT TO SURFACE AND INSTALL COVER 3) REAR OUTSIDE RECEPTACLE REPLACE COVER 4) INSTALL PROPER CORD ON DISPOSAL-ZIP CORD NOT TO BE USED FOR DISPOSAL 5) PROVIDE PHYSICAL FOR ROMEX FEEDING RECEPTACLE UNDER SINK 6) INSTALL ALL MISSING DEVICE COVERS (RECEPTACLES) 7) SMOKE DETECTORS ARE REQUIRED IN BEDROOMS (BATTERY OK) INSTALL PER INSTRUCTIONS ON DISTANCE FROM VENTS AND CORNERS 8) CORRECT AND RECALL