Inspection Status: Approved
Inspection History: ELECTRIC - FINAL
Permit Number - T03EL02237
Inspection Description - ELECTRIC - FINAL
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
11/18/2009 | ELECTRIC - FINAL | Approved | ||
07/29/2004 | ELECTRIC - FINAL | Denied | WATERBOND IS REQUIRED TO BE ATTACHED TO SOLID PIPE GOING INTO HOUSE | |
12/15/2003 | ELECTRIC - FINAL | Denied | IVRS - Inspection 0999*/ CANNOT HAVE ANY WATER ON GAS LINES BELOW SERVICE. WTR BOND NEEDS TO BE ATTACHED TO SOBEL PIPE TO INTERIOR./ A REFEE IS DUE BEFORE THE NEXT INSP. | |
11/24/2003 | ELECTRIC - FINAL | Denied | IVRS - Inspection 0999*/ 1) THE SERVICE MUST HAVE A CLEARANCE BELOW IT TO GRADE AND 3' OUT. THE WATER SOFTNER PIPES ARE IN THE WAY. 2) EACH APT. REQUIRES ITS OWN NEUTRAL - THERE IS ONLY ONE NEUTRAL FOR 2 APTS. 3) THERE MUST BE A PLASTIC BUSHING ON THE ONE INCH NIPPLE ENTERING THE SERVICE AND ONE ON THE 2" NIPPLE ENTERING BACK OF J-BOX IN ORDER TO PROTECT THE CONDUCTORS. 4) THE WATER LINE IS NOT BONDED. 5) DRIVE BOTH GROUND RODS TO GRADE OR BELOW AND STRAP GROUND WIRE TO WALL. 6) UPPER 2" STRAP TO BE INSTALLED MORE SECURELY, FACIA BOARD NOT TO BE USED. 7) PUSH BACK ALL WIRING IN J-BOX SO IT DOES NOT EXTEND BEYOND COVER WHEN COVER REMOVED. | |
11/17/2003 | ELECTRIC - FINAL | Denied | IVRS - Inspection 0920*/ DOGS! |