Permit: T03EL02210

Parcel: 131031220


Addresses:

5210 E 26TH ST

Inspection Status: Approved

Inspection History: ELECTRIC - FINAL

Date Description Inspector Results Comments
02/24/2004 ELECTRIC - FINAL Approved
12/08/2003 ELECTRIC - FINAL Denied IVRS - Inspection 0999*/ 1) DETACHED STORAGE: REMOVE ALL WIRING, IMPROPER AND NOT PERMITTED. IMPROPER TERMINATION OF GROUND ROD CONNECTION [NOT IN WEDGE] 2) A PERMIT REQUIRED FOR ALL NEW AND REWIRED CIRCUITS, INSTALLATION OR RE-INSTALLATION OF PLUMBING, ENCLOSED PORCH, PARTIALLY ENCLOSED CARPORT. A COMPLETE FLOOR PLAN WILL BE REQUIRED FOR ELECT., PLBG, MECH., AND BLDG. A GENERAL INSP. WILL BE ASSIGNED.
11/26/2003 ELECTRIC - FINAL Not ready for Inspection IVRS - Inspection 0000*
11/10/2003 ELECTRIC - FINAL Denied 1) THE PLASTIC BACKING THAT HOLDS THE BUS BAR INSIDE THE BREAKER AREA IN THE SERVICE PANEL HAS COME OFF IT'S SUPPORTS. 2) THE BRANCH CIRCUIT WIRING COMING IN AT BOTTOM OF SERVICE PANEL REQUIRED TO HAVE A PLASTIC BONDING TO PROTECT WIRES AS THEY ENTER THRU HOLE. 3) ONE 20 AMP CIRCUIT IS DOUBLE LUGGED - CANNOT HAVE 2 WIRES UNDER ONE TERMINATION. 4) SEAL HOLE AT BOTTOM OF PANEL. 5) 2 - 40 AMP CIRCUIT BREAKERS WITH # 10 WIRING SHOULD BE 30 AMP. 6) FRONT PORCH LIGHT TO BE WIRED CORRECTLY. 7) INSTALL ALL MISSING FIXTURES, COVER ALL SERVICES. 8) UNFINISHED WIRING IN DINING ROOM TO BE REMOVED. 9) BEDROOMS REQUIRED TO HAVE SMOKE DETECTORS. 10) WIRING IN WATER HEATER ROOM HAZARDOUS, CORRECT OR REMOVE. ALL OPEN SPLICES TO BE IN J-BOXES, PROTECT ALL ROMEX BELOW 8". REMOVE UNUSED WIRING, SUPPORT J-BOX ON BACK WALL. 11) SINCE THIS HOUSE IS VACANT, OBTAIN THE SERVICES OF A LICENSED ELECTRITIAN TO MAKE ALL CORRECTIONS AND PROVIDE NAME PRIOR TO NEXT INSPECTION.