Inspection Status: Approved
Inspection History: ELECTRIC - RECONNECT
| Date |
Description |
Inspector |
Results |
Comments |
| 11/10/2003 |
ELECTRIC - RECONNECT |
|
Approved |
IVRS - Inspection 0000*SENT TO TEP ON 1112AM |
| 10/28/2003 |
ELECTRIC - RECONNECT |
|
Denied |
IVRS - Inspection 0999*/ 1) CORRECT FIXTURE WIRING IN CARPORT, NEEDS OUTLET BOX 2) NORTH GROUND ROD AT SERVICE DRIVE TO GRADE, IT POSSES TRIP HAZARD 3) CORRECT OPEN SPLICE ABOVE REAR PORCH LIGHT. 4) NEUTRALS AND GROUNDS IN SUB-PANEL INSIDE TO BE ISOLATED REMOVE BAR (INSTALL COVER) 5) ROMEX IN SAME ROOM AS SUB PANEL TO BE COVERED (SHEET ROCK) 6) INSTALL MISSING FIXTURES AND MISSING DEVICE COVERS AND MISSING SMOKE DETECTORS 7) BEDROOMS TO HAVE SMOKE DETECTORS (BATTERY OK) 8) PLEASE CORRECT AND RECALL |
| 10/23/2003 |
ELECTRIC - RECONNECT |
|
Denied |
IVRS - Inspection 0920*/ NOTES: DWELLING LOCKED NO ACCESS INSIDE. MUST BE OPEN. SERVICE MUST HAVE PERMANENT ADDRESS LABEL. RE-CALL WHEN ACCESS AVAIL. |