Inspection Status: Approved
Inspection History: ELECTRIC - FINAL
| Date |
Description |
Inspector |
Results |
Comments |
| 09/03/2003 |
ELECTRIC - FINAL |
|
Approved |
IVRS - Inspection 0000*SENT TO TEP ON 0904AM |
| 08/29/2003 |
ELECTRIC - FINAL |
|
Denied |
IVRS - Inspection 0245*/NOTES: 1) INSTALL GROUNDING SYSTEM PER ART. 250 NEC. 2 - GROUND RODS REQUIRED. BOND GAS PIPING. 2) INSTALL PERMANENT ADDRESS LABEL. 3) I.D. CIRCUIT BREAKERS. 4) COMPLETE WIRING HOOK-UP TO SPA. 5) I.D. NEUTRAL SERVICE CONDUCTOR. 6) PLUG UNUSED OPENINGS AT BOTTOM OF PANEL. |
| 08/28/2003 |
ELECTRIC - FINAL |
|
Not ready for Inspection |
IVRS - Inspection 0000*/ OK GAS AND WATER LINE BELOW SERVICE. ONCE A STREET 'L' IS INSTALLED FOR SPIGHOT. |