Permit: T03EL01653

Parcel: 135061400

Inspection Status: Approved

Inspection History: ELECTRIC - FINAL

Date Description Inspector Results Comments
09/03/2003 ELECTRIC - FINAL Approved IVRS - Inspection 0000*SENT TO TEP ON 0904AM
08/29/2003 ELECTRIC - FINAL Denied IVRS - Inspection 0245*/NOTES: 1) INSTALL GROUNDING SYSTEM PER ART. 250 NEC. 2 - GROUND RODS REQUIRED. BOND GAS PIPING. 2) INSTALL PERMANENT ADDRESS LABEL. 3) I.D. CIRCUIT BREAKERS. 4) COMPLETE WIRING HOOK-UP TO SPA. 5) I.D. NEUTRAL SERVICE CONDUCTOR. 6) PLUG UNUSED OPENINGS AT BOTTOM OF PANEL.