Inspection Status: Approved
Inspection History: ELECTRIC - FINAL
| Date |
Description |
Inspector |
Results |
Comments |
| 09/12/2003 |
ELECTRIC - FINAL |
|
Approved |
IVRS - Inspection 0000* |
| 08/25/2003 |
ELECTRIC - FINAL |
|
Denied |
IVRS - Inspection 0999*/ 1) A PERMANENT METAL ADDRESS LABEL IS NEEDED 2) PLEASE LABEL CIRCUIT BREAKERS 3) A BONDING DEVICE IS NEEDED ON METER SIDE OF NIPPLE 250.94 4) OLD PANEL NOT APPROVED AS A JUNCTION BOX-PROVIDE AND APPROVED ENCLOSURE 5) FULLY IDENTIFY UNDGROUNDED CONDUCTOR-WHITE NOT APPROVED 6) STRAP GROUNDING ELECTRODE AND BONDING CONDUCTORS TO STRUCTURE 7) DOOR TO OPEN A FULL 90 DEGREE |
| 08/21/2003 |
ELECTRIC - FINAL |
|
Denied |
1) LOCKED, NO ONE HOME LEFT NOTICE ON SITE AND CALLED CONTRACTOR TO LEAVE MESSAGE TO RECALL. CALLED OUT BY S. LONG 11:00AM TO INSPECT WAS MISSED PREVIOUSLY |