Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO.
If you cannot find what you are looking for please
submit a records request.
Inspection Status: Approved
Inspection History: ELECTRIC - FINAL
| Date |
Description |
Inspector |
Results |
Comments |
| 09/22/2003 |
ELECTRIC - FINAL |
|
Approved |
IVRS - Inspection 0000* SENT TO TEP 093003 920AM |
| 09/15/2003 |
ELECTRIC - FINAL |
|
Denied |
IVRS - Inspection 0999*/ YOU HAVE TWO SINGLE POLE 30 AMP BREAKERS MARKED RECEPTACLE. NEED TO KNOW - SPECIFCALLY WHAT RECEPTACLE EACH SERVE. NEUTRAL NEEDS TO BE BONDED TO PANEL BOARD. USE MAIN BONDING JUMPER FACTORY PROVIDED. A RE INSPECTION FEE IS DUE BEFORE NEXT INSPECTION. |
| 09/08/2003 |
ELECTRIC - FINAL |
|
Denied |
IVRS - Inspection 0999*/ BOND NEUTRAL TO PANELBOARD WITH FACTORY MAIN BONDING JUMPER PROVIDED. SINGLE POLE 30 AMP BREAKER MARKED RECEPTACLER, PLEASE CHANGE ACCORDING TO RATING OF BRAND CIRCUIT. |
| 08/27/2003 |
ELECTRIC - FINAL |
|
Denied |
IVRS - Inspection 0999$ |
| 08/25/2003 |
ELECTRIC - FINAL |
|
Denied |
IVRS - Inspection 0999*/ 1) INSTALL FRICTION OR RUBBER TAPE AT SPLIT BOLT CONNECTIONS PER 90-4 NEC AND ART 110-3 (AT PANEL) 2) BOND NEUTRAL AND GROUNDING CONDUCTORS TO CABINET 3) NEC REQUIRES A MAIN DISCONNECT AT THE ELECTRIC PANEL OR MAIN BREAKER AT HOUSE 4) INSTALL BOND BUSHING AT 1 1/4" CONDUIT AT BOTTOM OR PANEL 5) WHAT DO THE 30 AMP SINGLE POLE BREAKERS FEED ? " IT SAYS RECEPTACLES" ? 6) NEED A SIGNED LETTER FROM HOMEOWNER THAT SERVICE FEEDER AMPACITY IS ADEQUATE FOR THE LOAD 7) 1 1/4" CONDUIT FITTING IS TOO SMALL |
| 08/15/2003 |
ELECTRIC - FINAL |
|
Not ready for Inspection |
IVRS - Inspection 0000* |
| 08/11/2003 |
ELECTRIC - FINAL |
|
Denied |
IVRS - Inspection 0999*/ 1) RODS ARE REQUIRED TO BE 6' APART MINIMUM-NOT 5' 2) WATER BOND GROUNDING CONDUCTOR ATTACHED TO WATER LINE ON WRONG SIDE OF DIELECTRIC UNION. THE ATTACHMENT MUST BE TOWARDS THE INTERIOR 3) LOOSE FITTINGS THROUGHOUT 4) SPLIT BOLT WIRE CONNECTORS REQUIRE MORE ELECTRICAL TAPE 5) SPLICED FEEDER WIRES REDUCED IN SIZE. I DO EXPECT A 200 AMP SERVICE AND SUB PANEL AS PER HEADING ON THIS PERMIT, OR A SIGNED LETTER FROM HOMEOWNER WOULD BE REQUIRED-PROVIDED THAT THE SERVICE FEEDER AMPACITY IS ADEQUATE FOR THE LOAD 6) EXISTING ROMEX PROTRUDING FROM BACK OF PANEL BOARD ARE RESTING ON AN UNPROTECTED SHARP KNOCKOUT 7) SEALING LOCKNUTS ARE REQUIRED IN CERTAIN AREAS 8) A NON RAIN TIGHT JUNCTION BOX INSTALLED, NEED NEMA-3 BOX |