Inspection History: ELECTRIC - RECONNECT

Date Description Inspector Results Comments
06/06/2003 ELECTRIC - RECONNECT Approved IVRS - Inspection 0000*/ 1) WILL NOTIFY TEP
06/05/2003 ELECTRIC - RECONNECT Denied IVRS - Inspection 0999*/ 1) ROMEX USED OUT SIDE FOR LIGHT AND SWITCH MUST BE PHYSICALLY PROTECTED ANYWHERE BELOW 8' 2) SMOKE DETECTOR TO BE IN BEDROOM 3) ROMEX IN CLOSET TO LIGHT NOT PROPERLY INSTALLED-LIGHT REQUIRED A BOX BEHIND IT AND ROMEX TO BE PROTECTED BELOW 8', SWITCH NEEDS COVER 4) THIS APARTMENT IS WIRED WITH AN UNDERGROUNDED SYSTEM-ALL RECEPTACLES HAVE TO BE OF A 2 WIRE 2 HOLE TYPE 5) CORRECT AND RECALL