Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit: T03EL00759

Parcel: 137100820


Addresses:

5425 S ALASKA DR

Inspection Status: Approved

Inspection History: ELECTRIC - SERVICE UPGRADE

Date Description Inspector Results Comments
06/05/2003 ELECTRIC - SERVICE UPGRADE Approved IVRS - Inspection 0000*
04/30/2003 ELECTRIC - SERVICE UPGRADE Partial Approval IVRS - Inspection 0000*SENT TO TEP ON 5/1/03 AT 9:15AM OK CABLE DROP OK TO CLEAR TEMP SERVICE.
1.) INSTALL PERMANENT ADDRESS LABEL ON SERVICE ENCLOSER, MUST BE SCREWED OR RIVITED.
2.) INSTALL W/P J-BOX FOR SUB PANEL SPLICES, AND GROUND.
3.) BOND GAS PIPING.
4.) SUPPORT RISER.
NOTE THAT TEMP POWER AND CABLE DROP WILL ALLOW THE OWNER TO COMPLETE WORK ON SERVICE, DUE TO ROOFING INSTALL.