Inspection Status: Denied

Inspection History: ELECTRIC - FINAL

Date Description Inspector Results Comments
04/03/2003 ELECTRIC - FINAL Denied IVRS - Inspection 0999*
1.) THE 15AMP CIRCUIT IS TO BE ON ITS OWN COMING FROM PANEL NOT TIED INTO AN EXISTING CIRCUIT.
2.) SCHEDULE 40 PVC PIPE CANNOT BE USED OUTSIDE MUST BE SCH 80.
3.) UNDERGROUND BURIED WITHOUT INSPECTION UNCOVER
4.) RECEPTACLES AND SWITCH BOXES WIRED INCORRECLTY, RECEPTACLES AND SWITCH BOXES WIRED INCORRECTLY, RECEPTACLE BOX NOT GROUNDED, SWITCH GROUNDS MUST ALL TIE TOGETHER AND WIRE.
5.) UF CABLE MUST BE PROTECTED FROM STANDING PLAT FORM TO 8' HEIGHT, INSTALL IN CONDUIT OR BEHIND WALL COVER.
6.) ENTRY OF UF CABLE INTO PLAYHOUSE MUST BE PHYSICALLY PROTECTED.