Inspection History Details
Inspection Status: Approved
Inspection History: ELECTRIC - FINAL
Permit Number - T03EL00521
Inspection Description - ELECTRIC - FINAL
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
04/04/2003 | ELECTRIC - FINAL | Approved | IVRS - Inspection 0000*SENT TO TEP ON 4/7/03 AT 9:15AM | |
03/24/2003 | ELECTRIC - FINAL | Denied | IVRS - Inspection 0210* REPAIRS/CORRECTIONS REQUIRED. 1.) THE ELECTRIC POWER PEDESTAL DOOR IS LOOSE. 2.) PLEASE BLANK COVERS OVER CIRCUIT BREAKER OPEN SPACE. 3.) PLACE BLANK COVER OVER CONDUIT KNOCK OUT HOLE IN FRONT OF PANEL/ PEDESTAL BELOW CIRCUIT BREAKER PANEL. 4.) EACH BEDROOM MUST HAVE A SMOKE DETECTOR. KEEP SMOKE DETECTORS A MINIMUM OF 3 FT. AWAY FROM AIR SUPPLY DUCTS. |