Permit: T03EL00521

Parcel: 108201000

Inspection Status: Approved

Inspection History: ELECTRIC - FINAL

Permit Number - T03EL00521

Inspection Description - ELECTRIC - FINAL

Inspection Status - Approved

Date Description Inspector Results Comments
04/04/2003 ELECTRIC - FINAL Approved IVRS - Inspection 0000*SENT TO TEP ON 4/7/03 AT 9:15AM
03/24/2003 ELECTRIC - FINAL Denied IVRS - Inspection 0210*
REPAIRS/CORRECTIONS REQUIRED.
1.) THE ELECTRIC POWER PEDESTAL DOOR IS LOOSE.
2.) PLEASE BLANK COVERS OVER CIRCUIT BREAKER OPEN SPACE.
3.) PLACE BLANK COVER OVER CONDUIT KNOCK OUT HOLE IN FRONT OF PANEL/ PEDESTAL BELOW CIRCUIT BREAKER PANEL.
4.) EACH BEDROOM MUST HAVE A SMOKE DETECTOR. KEEP SMOKE DETECTORS A MINIMUM OF 3 FT. AWAY FROM AIR SUPPLY DUCTS.