Permit: T03EL00341

Parcel: 136333530


Addresses:

2922 S HARRISON RD

Inspection Status: Approved

Inspection History: ELECTRIC - FINAL

Date Description Inspector Results Comments
03/04/2003 ELECTRIC - FINAL Approved IVRS - Inspection 0000*OK TO CLEAR SENT TO TEP ON 3/5/03 AT 9:15AM.
02/28/2003 ELECTRIC - FINAL Denied IVRS - Inspection 0999*
1.) FASTEN ADDRESS TAG W/RIVETS OR SCREWS.
2.) WILL NEED A MAIN BREAKER FOR SERVICE.
3.) DRIVE RODS FLUSH OR BELOW GRADE.
4.) MULTIPLE CONDUCTORS UNDER/LUG AND COPPER NAD ALUMIUMN MIXED.
5.) A PERMIT WILL BE REQUIRED FOR THE ADDITION OF AN A/C COMPRESSOR AND COIL UNIT AT TOP OF FURANCE.
A PERMIT FOR THIS TO BE POSTED PRIOR TO ELECTRICAL FINAL.