Inspection History: ELECTRIC - FINAL

Date Description Inspector Results Comments
08/14/2003 ELECTRIC - FINAL Approved IVRS - Inspection 0000*
02/27/2003 ELECTRIC - FINAL Denied IVRS - Inspection 0245*NOTES
1.) INSTALL PERMANENT ADDRESS ON SERVICE PANEL.
2.) INSTALL BREAKER BLANK ON PANEL DEADFRONT OUTSIDE.
3.) ROMEX WIRING BELOW 8' NEED TO BE PROTECTED, IN CONDUIT OR DRYWALL OVER WOOD STUDS, (WASHROOM AREA) ALSO SPLICES NEED TO BE IN APPROVED J-BOX WITH COVER.
4.) SMOKE DETECTOR REQUIRED IN BEDROOM.
5.) SWAMP COOLER NEEDS TO BE WIRED PROPERLY.
OUTSIDE USE MIDWEST COOLER BOX AND CONDUIT FOR WIRING. EXPOSED WIRING NOT ALLOWED.