Inspection History Details
Inspection Status: Approved
Inspection History: ELECTRIC - RECONNECT
Permit Number - T03EL00282
Inspection Description - ELECTRIC - RECONNECT
Inspection Status - Approved
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 02/28/2003 | ELECTRIC - RECONNECT | Approved | IVRS - Inspection 0000*OK TO CLEAR RECONN. | |
| 02/21/2003 | ELECTRIC - RECONNECT | Denied | IVRS - Inspection 0165* 1.) THE BEDROOM MUST HAVE A SMOKE DETECTRO MOUNT A MINIMUM OF 3FT. AWAY FROM THE AIR REGISTER. IF ON WALL IT MUST BE NOT LOWER THAN 12" NOR CLOSER THAN 6" TO CIELING. IF MOUNTED ON CIELING IT MUST BE 16" AWAY FROM WALL OR ANY CORNER. 2. ) PUT BLANK COVERS ON OPEN CIRCUIT BREAKER SPACES ON PANEL (IN CLOSET.) THANK CORRECT & RECALL. |