Permit: T03EL00282

Parcel: 106020950

Inspection Status: Approved

Inspection History: ELECTRIC - RECONNECT

Permit Number - T03EL00282

Inspection Description - ELECTRIC - RECONNECT

Inspection Status - Approved

Date Description Inspector Results Comments
02/28/2003 ELECTRIC - RECONNECT Approved IVRS - Inspection 0000*OK TO CLEAR RECONN.
02/21/2003 ELECTRIC - RECONNECT Denied IVRS - Inspection 0165*
1.) THE BEDROOM MUST HAVE A SMOKE DETECTRO MOUNT A MINIMUM OF 3FT. AWAY FROM THE AIR REGISTER. IF ON WALL IT MUST BE NOT LOWER THAN 12" NOR CLOSER THAN 6" TO CIELING. IF MOUNTED ON CIELING IT MUST BE 16" AWAY FROM WALL OR ANY CORNER.
2. ) PUT BLANK COVERS ON OPEN CIRCUIT BREAKER SPACES ON PANEL (IN CLOSET.) THANK
CORRECT & RECALL.