Permit: T03EL00280

Parcel: 106041450


Addresses:

3407 N 2ND AV #1103

Inspection Status: Approved

Inspection History: ELECTRIC - FINAL

Date Description Inspector Results Comments
03/05/2003 ELECTRIC - FINAL Approved IVRS - Inspection 0000*SENT TO TEP ON 3/4/03 AT 9:15AM OK TO CLEAR UNIT 2102 ONLY OTHERS CLEARED.
03/03/2003 ELECTRIC - FINAL Partial Approval IVRS - Inspection 0000*1.) OK TO SEND CLEARANCE FOR UNITS 1104-1107 AND 2104.
2.) UNIT 2102 HAS NOT BEEN FITTED WITH SMOKE DETECTORS.
02/20/2003 ELECTRIC - FINAL Denied IVRS - Inspection 0165*
EACH BEDROOM MUST HAVE A SMOKE DETECTOR THESE MAY BE BATTERY OPERATED.
MOUNTING LOCATION SHOULD BE.
1.) 3 FT. DISTANCE TO SUPPLY AIR GRILL/OPENING.
2.) ON WALL NOT CLOSER THAN 6" TO CIELING OR LOWER THAN 12" FROM CIELING.
3.) IF CIELING MOUNTED NOT CLOSER THAN 16" TO WALL OR CORNER. INSTALL AND RECALL INSPECTION.