Inspection History Details
Inspection Status: Approved
Inspection History: ELECTRIC - FINAL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 06/30/2003 | ELECTRIC - FINAL | Approved | IVRS - Inspection 0000*/ 1) OK TO CLEAR | |
| 06/23/2003 | ELECTRIC - FINAL | Denied | IVRS - Inspection 0999*/ 1) PLEASE SECURE RISER SUPPORT-1/4" MINIMUM HARDWARE 2) IDENTIFY GROUNDING CONDUCTOR AT TERMINAL 3) SUPPORT CONDUIT AS PER CODE 4) SECURE GROUNDING ELECTRODE CONDUCTOR WITH APPROVED MEANS-TY WRAPS ARE NOT UV RATED 5) BOND JUNCTION BOX ENCLOSURE WITH SPLICES | |
| 02/20/2003 | ELECTRIC - FINAL | Denied | IVRS - Inspection 0999* 1.) PERMANENT ADDRESS ON SERVICE REQUIRED 2.) WHEN A SERVICE IS INCREASED OR UPGRADED IT MUST COMPLY WITH 99 NEC 110-26 COMPLETE CLEARANCE DOWN TO GROUND THE WIDTH OF SERVICE OR 30" IS REQUIRED GAS METER CANNOT BE INFRONT OF NEW PANEL. 3. NEED AC PERMIT. |