Permit: T03EL00101

Parcel: 138212500


Addresses:

561 W ARAGON RD

Inspection Status: Approved

Inspection History: ELECTRIC - FINAL

Date Description Inspector Results Comments
05/13/2003 ELECTRIC - FINAL Approved IVRS - Inspection 0000*
05/09/2003 ELECTRIC - FINAL Denied IVRS - Inspection 0245*
01/31/2003 ELECTRIC - FINAL Denied IVRS - Inspection 0245*1.) NO COMPLIANCE WITH NOTES #3 LAST INSP. STORAGE ROOM IN CARPORT.
2.) ITEM #5 PERMIT REQUIRED.
3.) LIGHT FIXTURES, SMOKE DETECTOR, RECEPT COVERS MISSING.
4.) DOORS MUST BE UNLOCKED FOR INSPECTIONS.
5.) A REINSPECTION FEE WILL BE ASSESSED NEXT INSPECTION IF NOT COMPLETE.
01/22/2003 ELECTRIC - FINAL Denied IVRS - Inspection 0245*1.) INSTALL PERMANENT ADDRESS LABEL ON SERVICE. MUST BE SCREWED OR RIVITED TO SERVICE ENCLOSURE.
2.) RE SUPPORT COOLER MIDWEST BOX ON ROOF.
3.) ROMEX WIRING EXPOSED BELOW 8' MUST BE COVRED.
4.) ROMEX INSTALLED UNDER SOUTH & WEST ROOF OVERHANG TO BE TERMINATED IN APPROVED W/P J-BOX AND SUPPORTED PER NEC. WITHIN 12" EACH TERMINATION AND AT 4 1/2' INTERVALS.
5.) MUST HAVE PERMIT & INSPECTION FOR REPLACEMENT OF MECHANICAL HEATING & COOLING.
6.) INSTALL APPROVED J-BOX OVER LIGHT FIXTURE IN CARPORT.