Permit: T03EL00061

Parcel: 107111950


Addresses:

50 E DELANO ST


Inspection Status: Approved

Inspection History: ELECTRIC - FINAL

Permit Number - T03EL00061

Inspection Description - ELECTRIC - FINAL

Inspection Status - Approved

Date Description Inspector Results Comments
06/04/2003 ELECTRIC - FINAL Approved IVRS - Inspection 0000*
05/30/2003 ELECTRIC - FINAL Denied IVRS - Inspection 0910*/ 1) LOOSE DOG IN YARD. ARRANGE TO HAVE DOG RESTRAINED. RECALL INSPECTION. RE-INSPECTION FEE WILL BE LEVIED. 3RD VISIT
05/28/2003 ELECTRIC - FINAL Denied IVRS - Inspection 0210*/ 1) WHERE IS GAS LINE BOND ? 2) WHERE IS LABEL ?
05/13/2003 ELECTRIC - FINAL Denied IVRS - Inspection 0245*GROUND IS INCORRECT.
2.) NEED PERM. ADDRESS ON METER
3.) IDENTIFY CIRCUIT BREAKERS IN PANEL.
04/30/2003 ELECTRIC - FINAL Denied IVRS - Inspection 0215*CORRECTION REQUIRED.
1.) THE MAST MUST BE BRACED TO THE BUILDING BECAUSE IT EXCEEDS THE MAXIMUM HEIGHT.
2.) A SECOND STRAP IS REQUIRED, BETWEEN THE BOX AND PARAPET, ON THE RISER CONDUIT. THE FIRST ONE SHOULD BE APPROX. 8" ABOVE THE PANEL BOX.
3.) WHERE IS THE COLD WATER AND GAS PIPE BOND? WHERE IS PAPERWORK? IS ADDRESS CORRECT? THIS REQUEST SAYS 50 E. DELANO. THANKS.
04/18/2003 ELECTRIC - FINAL Denied IVRS - Inspection 0999*DOG IN YARD MUST TIE UP OR LOCK UP. PLEASE RECALL.