Inspection Status: Partial Approval
Inspection History: ELECTRIC - FINAL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 05/02/2003 | ELECTRIC - FINAL | Partial Approval | IVRS - Inspection 0000*1.) MAINTAIN WORKING CLEARANCE INFRONT OF KITCHEN PANEL AS DISCUSSED. 2.) CHECK GAS BOND. |
|
| 01/09/2003 | ELECTRIC - FINAL | Denied | IVRS - Inspection 0999* *REMOVE EXTENSION CORD WIRING AT KITCHEN CABINET (EAST OF SINK). * ZIP CORD WIRING IS NOT ACCEPTABLE AT DISPOSAL SWITCH & DISPOSAL *OPEN SPLICE AT DISPOSAL NOT ALLOWED *REMOVE EXTENSION CORD AT HALL BATH. *GROUNDING TYPE RECEPTACLES NOT ALLOWED ON UNDERGROUND CIRCUITS UNLESS GFCI PROTECTE. *OPEN LAMP FIXTURES NOT ALLOWED IN BEDROOM CLOSETS (REMOVE AND REPLACE.) *SMOKE DETECTORS IN HALL MISSING BATTERY (INSTALL SMOKE DETECTORS AT ALL BEDROOMS) *REMOVE PLUG STRIP AT EAST BATHROOM OR INSTALL PER NATIONAL ELEC. CODE. * INSTALL ALL COVERS, PLATES ETC. WHEN PAINTING IS COMPLETED.* IMPROPER TAP AT MAIN SERVICE. * PROPERLY WIRE THE WORK SHED OUT BACK *OUTDOOR RECEPTACLES NEEDS TO BE WEATHER PROOF AND GFCI PROTECTED. |