Inspection History Details
Inspection Status: Correction Required
Inspection History: INSP - INITIAL CODE ENFORCMENT
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 11/17/2003 | INSP - INITIAL CODE ENFORCMENT | Correction Required | RECEIVED INSP REQUEST FOR 1409 W SAINT CLAIR UNIT A FOR COMPLAINT WAS 1. NO HEATER. 2. LEAKS IN BATHROOM AND KITCHEN. 3. NO GAS - CANNOT TURN ON . 4. ELECTRICAL PROBLEMS WITH SWITCHES, POSSIBLE SHORTING. 5. KIDS SICK. 6. NO STOVE. CONTACTED OWNER RAMON LEON. ASKED OWNER IF GAS WAS OFF TO UNIT A DUE TO ON GOING WORK BEING CONDUCTED BY HIM. REPLIED GAS SERVICE FOR UNIT A WAS IN TENANT'S NAME AND WAS UNAWARE OF ANY PROBLEMS WITH ELECTRICAL SWITCHES AND SHORTS. INQUIRED ABOUT NO STOVE, OWNER STATED RENTAL DID NOT COME WITH STOVE AND TENANT WAS TO PROVIDE HER OWN STOVE. OWNER ALSO STATED THAT TENANT WAS BEHIND ON HER RENT. ASKED OWNER IF HE WOULD BE HOME INCASE HE NEEDED TO BE REACHED FOR FURTHER ACTION, REPLIED HE WOULD BE HOME. ASKED OWNER ABOUT NUMBER OF PERSON IN UNIT. OWNER STATED (6) ALL TOGETHER AND TENANTS OWE $234.00 FOR OCTOBER AND $435.00 FOR NOVEMBER. CONTACTED SOUTHWEST GAS CO AND REQUESTED INFORMATION ON THIS ADDRESS. SW PERSONNEL STATED SW SERVICE HAS BEEN OFF SINCE MAY 7TH, 2003. FOR LACK OF PAYMENT AND OWULD HAVE TO PAY PARTIAL BILL AND DEPOSIT FOR RECONNECTION. INFORMED CECI CRUZ GAS SERVICE HAD BEEN SHUT OFF DUE TO LACK OF PAYMENT ON TENANTS BEHALF AND SERVICE WAS IN HER NAME. TENANT HAD STATED ON COMPLAINT FORM GAS SERVICE WAS OFF DUE TO OWNER WAS WORKING ON SYSTEM. C. CRUZ CONTACTED TENANT BY PHONE AND MADE TENANT AWARE SHE WAS ON SPEAKER PHONE AND INP. LOPEZ WAS PRESENT. C. CRUZ INFORMED TENANT THAT INFORMATION RECEIVED FROM SW GAS INDICATED SHE WAS RESPONSIBLE FOR GAS SERVICE, TENANT REPLIED YES SHE WAS. BUT COULD NOT TURN ON HEATER DUE TO OWNER HAD PULLED OFF YELLOW TAG LEFT BY SW GAS TECH. CONDEMNING UNIT. TENANT WAS ASKED HOW MANY PERSONS WERE LIVING IN UNIT, TENANT STATED 6 ALL TOGETHER, HER, HER HUSBAND, AND 4 CHILDREN. C. CRUZ INFORMED TENANT THAT INSP LOPEZ WOULD DO INSPECTION TODAY. VISITED SITE MET TENANT, TENANT STATES SEVERAL PROBLEMS WITH UNIT, TERMITES, ELECTRICAL, WINDOWS. ENTER UNIT, FOUND COVER OF WALL FURNACE HAD BEEN PULLED OFF. TENANT POINTED OUT T-STAT WIRE AND STATED SW TECH INFORMED HER THAT THOSE WIRES WERE NOT CORRECT AND SHOULD OF BEEN SOLID. INFORMED HER THAT T-STAT WIRES WERE CORRECT AND INSTALLATION SEEMED PROPER. UNIT DOES NEED TO BE SERVICED. CONTACTED SW GAS CO., REQUESTED INFORMATION CONCERNING ANY COMPLAINTS REGARDING FURNACE (WALL). SW PERSONNEL INFORMED INSP. THAT IN AUGUST 29, 2002 UNIT WAS TAGGED FOR HAZARDOUS CONDITIONS. ALSO RECORDS SHOWS 2 TURN ONS HAVE BEEN DONE AND NO PROBLEMS WITH UNIT WERE ON RECORDS SINCE JAN. 3RD OF 02. CONTACTED OWNER INFORMED HIM WALL FURNACE WILL NEED TO BE SERVICED BEFORE GAS SERVICE IS RESTORED AND WILL REQUIRE HEATING CONTRACTOR TO DO SO. OWNER'S SON WORKS FOR RUSSETT CO. FATHER (RAMON) REQUESTED I EXPLAIN TO SON (RAY JR) VIOLATION FOUND IN UNIT. EXPLAINED TO RAY JR WALL FURNACE WILL REQUIRE SERVICE AND PLUMBER WILL NEED TO CLEAR KITCHEN DRAIN. STATED PLUMBER WILL BE SENT TOMORROW 11/18/03 AND THE EARLIEST HE COULD GET A HEATING TECH ON SITE WOULD BE 11/19/03. ON SITE INSP. RELAYED INFORMATION TO TENANT AND SHE AGREED. CONTINUED WITH INSPECTION OF INTERIOR, 1. FOUND TERMITE INFESTATION THROUGHOUT UNIT, ALL DOOR FRAMES SHOW STRONG SIGNS OF TERMITE DAMAGE. 2. BEDROOM ENTRY DOOR NORTHSIDE HAS SEVERAL HOLES. FOUND SPACE HEATER IN 2 ROOMS. NORTHSIDE AND WESTSIDE, NS HAD HEATER ON TOP OF SMALL DRESSER AND SUITCASE SITTING ON TOP. WS HEATER WAS ON SMALL TABLE NEXT TO BUNK BEDS. INFORMED TENANT NOT TO USE SPACE HEATERS DUE TO BEING A FIRE HAZARD AND COULD CAUSE ELECTRICAL PROBLEMS DUE TO SERVICE IS ON 60 AMPS. STATED OWNER HAD GIVEN HER BOTH HEATERS DUE TO BEDROOM WINDOWS WERE ALLOWING COLD AIR INTO BEDROOMS. 3. CHECKED BEDROOM WINDOW FOUND FRAME STYLE HAD COME LOOSE AND NOT SEALING PROPERLY IN NS BEDROOM AND 1 WINDOW MISSING AT WEST BEDROOM. ALSO BUNKBEDS WERE BLOCKING EGRESS FROM ROOM ALSO FOUND BROKEN WINDOW IN LIVINGROOM. 4. HOLES WERE FOUND IN WALLS THROUGHOUT UNIT. 5. NO SMOKE ALARMS WERE FOUND IN UNIT. ASKED TENANT HOW SHE WAS COOKING MEALS, REPLIED SHE WAS USING ELECTRIC SKILLETS AND MICROWAVE OVEN AND COMPLAINED ABOUT OUTLETS NO LONGER HOLDS ANY PLUG. 6. CHECKED RECEPTACLES, FOUND SEVERAL 3 PRONG RECEPTACLES NON GROUNDED AND TWO PRONG RECEPTACLES WORN OUT, NO GFCI IN KITCHEN SINK AREA. SOUTH BEDROOM HAS SUBPANEL WITH BREAKER THAT APPEARS WAS INSTALLED WITHOUT PERMITS AND NONE OF BRANCH CIRCUITS ARE LABELED ALSO HAS 3 PRONG RECEPTACLES GANG BOX WITH UNPROTECTED ELECTRICAL CONDUCTOR. BED IS BLOCKING 3 FOOT WORK AREA FOR EASY ACCESS OF PANEL. OWNER IN PROCESS OF DOING ELECTRICAL UPGRADE TO STRUCTURE, NEW PANEL (DISCONNECT) HAS BEEN INSTALLED BUT IS LACKING TEP RECONNECT. BEDROOM CEILING FAN LIGHT FIXTURE HANGING FROM ELECTRICAL CONDUCTORS. RANGE HOOD DOES NOT WORK. ASKED ABOUT STOVE, TENANT REPLIED NO STOVE WAS INCLUDED IN RENTAL AGREEMENT. TENANT DID HAVE PROPANE GRILL IN KITCHEN AREA AND WAS ASKED IF SHE WAS USING GRILL. TENANT STATED, NO. TENANT ALSO STATED THAT MAIN BREAKER SOMETIME TRIPS OFF AND WHEN TRYING TO RESET, BREAKER WILL NOT RESET RIGHT AWAY HAS TO WAIT AWHILE TO RESET, STATED THIS ONLY HAPPENS WHEN USING ELECTRIC SKILLETS AND MICROWAVE. 7. KITCHEN SINK WAS CLOGGED, NOTICED FOOD STUBS AND GREASE FLOATING IN WATER. TENANT STATED SINK PLUGGED UP ALL THE TIME AND LEAKS FROM PLUMBING UNDERNEATH OPENED DRAWERS AND FOUND CONTAINER WITH SOME WATER, CABINET FLOOR WAS NOT WET BUT DID SHOW SIGN OF LEAK AT SOMETIME, CABINET DRAWERS WERE FOUND HANGING FROM HINGES. 8. FLOORING THROUGHOUT UNIT IS CRACKED AND SECTIONS HAVE CHIPPED OFF ALONG WITH SEVERAL BROKEN TILES. SE BEDROOM, EASTWALL HAS COPPER PIPING COMING THROUGH. MAY HAVE BEEN HOT WATER AND STORAGE ROOM AT ONE TIME. 9. ENTRY DOOR IN SAME ROOM WAS BLOCKED BY DRESSER AND LARGE MIRROR. 10. DID NOTICE WEATHER STRIPPING AND THRESHOLD LACKING OF EXTERIOR DOORS LARGE AMOUNT OF LIGHT SHINNING THROUGHOUT. WILL HAVE TO DO RESEARCH IN RECORDS AT DSD ON UNIT FOR WOP OF ADDITIONS OF LIVING SPACE CONVERSION OF STORAGE INTO LIVING SPACE AND ADDITION OF ELECTRICAL AND PLUMBING. ANOTHER BATHROOM HAS BEEN ADDED. ASKED TENANT IF ANY OTHER PROBLEMS IN UNIT, TENANT STATED BATH ON SOUTH SIDE SHOWER FIXTURE LEAKS AND LAVE. SINK FAUCET COLD SIDE WILL NOT TURN ON. CHECKED LAVE FAUCET, FOUND HANDLE STRIPPED, CHECKED HOT SIDE AND NO WATER FLOWING, THOUGHT, ASKED TENANT IF FANGLE STOPS WERE OFF. TENANT REPLIED THERE WAS NO WATER, ASKED TENANT TO CLARIFY NO WATER, SHE STATED WATER SERVICE HAD BEEN SHUT OFF DUE TO LACK OF PAYMENT. INFORMED TENANT DUE TO (2) UTILITIES BEING OFF AT SAME TIME THERE WAS A GOOD CHANCE I WOULD HAVE TO POST UNIT UNFIT TO OCCUPY AND THAT TENANT SHOULD OF MADE MENTION OF NO WATER SERVICE WHEN MAKING COMPLAINT THIS MORNING AND HWEN BOTH C. CRUZ AND I WERE TALKING TO HER ON SPEAKER PHONE. I TOLD HER THAT PLACING HER IN TEMPORARY HOUSING COULD NOT BE DONE AFTER 2:00 PM. ASKED IF SHE HAD ANY PLACE TO STAY FOR THE NIGHT. SHE REPLIED SHE COULD STAY AT HER DAUGHTER'S FOR TONIGHT AND TOMORROW. SHE COULD HAVE THE WATER TURNED BACK ON. I REPLIED SHE COULD MOVE BACK INTO UNIT IF THE WATER WAS TURNED BACK ON AND FOR HER TO CONTACT ME SO I COULD VERIFY WATER BEING TURNED ON. ALSO EXPLAINED TO TENANT THAT GAS SERVICE MUST BE RESTORED WITHIN 48 HOURS. SHE REPLIED THAT WOULD BE ACCEPTABLE. I INFORMED HER I WOULD CONTACT INSP. II AND DO PAPER WORK IN TRUCK AND ISSUE VIOLATION TO BOTH OWNER AND TENANT. CONTACTED INSP. II, R. SALDATE INFORMED HIM TENANT HAD JUST NOTIFIED ME THAT WATER SERVICE WAS SHUT OFF THIS MORNING. INFORMED INSP II THAT TENANT AND I HAD REACHED AGREEMENT. SHE WILL BE STAYING AT THER DAUGHTER'S APT. TILL TOMORROW AND SHE WILL MAKE ARRANGEMENTS TO RESTORE WATER SERVICE AND CONTACT ME WHEN WATER SERVICE IS RESTORED. INSP II RECOMMENDATION WS DUE TO (2) SERVICES WERE OFF THE UNIT SHOULD BE POSTED UNFIT TO OCCUPY AND REMOVED POSTING AFTER WE RECEIVE CONFIRMATION OF WATER SERVICE. I AGREED WITH SUGGESTION AND INFORMED INSP. II I WOULD EXPLAIN TO TENANT OUR DECISION. MADE CONTACT WITH TENANT, INFORMED HER DUE TO BOTH UTILITIES BEING OFF, UNIT WOULD BE POSTED UNFIT TO OCCUPY AND IF FOUND IN UNIT AFTER DARK SHE WOULD BE ASKED TO LEAVE AND POSSIBLY BE REMOVED FROM UNIT BY POLICE AS LONG AS UNIT IS POSTED. EXPLAINED TO HER SHE COULD RETURN AFTER INSP LOPEZ HAD RECEIVED CONFIRMATION OF WATER SERVICE HAD BEEN RESTORED. SHE ASKED IF SHE COULD RETURN FOR CLOTHES DURING DAYTIME AND I REPLIED YES JUST DON'T STAY FOR EXTENDED PERIOD OF TIME. SHE THAN AGREED. I INFORMED HER I HAD TO RETURN TO OFFICE TO PRINT OUT NOTICE AND UNFIT TO OCCUPY POSTING AND WOULD RETURN WITHIN THE NEXT COUPLE OF HOURS. RETURNED TO OFFICE, RE-WROTE NOTICE FOR POSTING. REQUESTED INSP. II COME ALONG IN CASE OF ANY PROBLEM. ARRIVED AT ADDRESSS ABOVE APPROX. AT 7:30 PM. TENANTS WERE STILL AT PROPERTY. MADE CONTACT WITH TENANT ASKED IF EVERYTHING WAS READY TO GO. TENANT REPLIED SHE WAS NOT GOING ANYWHERE AND THAT HER DAUGHTER'S PLACE WAS TO SMALL FOR HER FAMILY TO STAY THERE. EXPLAINED TO HER WE HAD AN AGREEMENT BEFORE I LEFT TO REWRITE PAPER WORK FOR POSTING. TENANT RESPONDED NO, THAT THE CITY HAS TO MAKE ACCOMADATIONS FOR HER AND HER FAMILY. INSP RESPONDED THAT ARRANGEMENTS COULD NOT BE MADE THIS LATE. TENANT THEN PICKED UP PHONE AND STATED SHE WAS CALLING THE POLICE DUE TO THE CITY WAS KICKING HER OUT OF HER UNIT. INSPECTOR R. SALDATE WAS ON SITE. I INFORMED HIM THAT TENANT REFUSED TO LEAVE. INSP SALDATE TRIED SEVERAL TIMES TO EXPLAIN STEPS THE CITY HAS TO GO THROUGH AND WHY HER UNIT WAS BEING POSTED. TENANT BECAME UNRULY AND REFUSED TO BE MOVED AND KEPT INSISTING THE CITY HAD TO PLACE HER IN ANOTHER UNIT DUE TO LANDLORD WAS NOT MAKING REPAIRS. INSPECTOR SALDATE THEN CONTACTED 911 COMMUNICATION AND REQUESTED FOR AN OFFICER TO KEEP THE PEACE AND WILL NEED SOMEONE TO TRANSLATE DUE TO TENANT ONLY SPEAKS SPANISH. AFTER SOMETIME PASSED (2) OFFICERS ARRIVED, ONE FOR THE TENANT AND ONE TO PRESERVE THE PEACE. BOTH INSPECTORS EXPLAINED WHAT WAS GOING ON BUT NEITHER OFFICERS SPOKE SPANISH, OFFICER THEN CALLED FOR SOMEONE WHO SPOKE SPANISH. OFFICER I. ROMERO AND HAMMACKED ARRIVED ON SITE. WENT THROUGH THE WHOLE EXPLAINATION OF WHY THE UNIT WOULD BE SHUT DOWN. AFTER AN HOUR AND HALF TENANT FINALLY AGREED TO LEAVE THEN STATED SHE HAD NO TRANSPORTATION FOR HER AND THE CHILDREN. INSPECTOR LOPEZ ASKED TENANT IF SHE HAD ANY OTHER FRIENDS, RELATIVES, NEIGHBORS WHO COULD GIVE HER A RIDE. TENANT STATED NO. AFTER SOME CONVERSATION WITH TPD OFFICERS THEY MADE CONTACT WITH VICTIM WITNESS PROGRAM VOLUNTEERS VICTIM ADVOCATE BETWEEN OFFICERS AND VOLUNTEERS AND FAMILY MEMBERS COULD BE TRANSFORMED TO ROADWAY INN. TENANT HAD TO PROVIDE (1) INFANT SEAT AND VICTIM WITNESS CAME UP WITH ANOTHER SEAT. TENANT ASKED WHO WAS GOING TO TRANSPORT CHILDREN IN MORNING TO SCHOOL. TENANT WAS TOLD BY OFFICERS SHE WILL HAVE TO MAKE SOME TYPE OF ARRANGEMENTS FOR CHILDREN. INFORMED TENANT TO CONTACT ME WHEN GAS AND WATER SERVICES HAD BEEN RESTORED THEN CITY WOULD RELEASE UNIT FOR RE-OCCUPANCY. ALSO REMINDED HER SHE HAD AN APPOINTMENT WITH TRAVELER'S AID TUESDAY 11/18/03 AT 7:30 AM FOR ASSISTANCE. ALL WERE LOADED INTO TRANSPORTATION AND UNIT WAS POSTED UNFIT TO OCCUPY. WILL AWAIT CALL FROM TENANT REGARDING RESTORATION OF GAS AND WATER SERVICES. DO FOLLOW UP IN 4 DAYS. |